HUUM HIVE Flow LS Wood-Burning Sauna Heater for sauna rooms of 8-18 m³, 150 kg stone capacity. Chimney and protective bedding are sold separately. Delivery in 30 business days. Prices exclude VAT.
Specifications
| Heater output | 9.8 kW |
|---|---|
| Sauna room size | 8-18 m³ |
| Dimensions (W x D x H) | 526 x 706 x 884 mm |
| Weight | 73 kg |
| Stone capacity | 150 kg |
| Minimum safety clearances | side 150 mm, front 500 mm, rear 150 mm, ceiling 1000 mm, floor non-combustible base; see notes mm |
| Compatible controllers | not applicable (wood-fired) |
| HUUM code | H1016011 |
| EAN | 4744103015290 |
Installation notes (from the HUUM manual)
- Floor of non-combustible material with sufficient load capacity (e.g. concrete >=50 mm); on a combustible floor the HUUM thermal plate/protective bedding (or equivalent) is mandatory with >=30 mm ventilation gap.
- Safety distances to flammables: back 150 mm, side 150 mm, above 1000 mm (declaration of performance); door side B = 500 mm (Table 1/Fig. 7).
- At least 50 mm between a non-combustible wall and the stove; protective screens reduce distances by 50% (single) / up to 75% (double); ceiling -25% with single screen.
- Combustible floor in front: metal plate >=100 mm beyond door sides and >=400 mm in front (HUUM floor protective plate 420 x 450 mm).
- Chimney: T450, min cross-section 10 400 mm2, leg Ø 114 mm; top or back connection; average flue gas temp below 400 C so may share an existing flue if local authorities approve.
- Heat outdoors once before installation with door slightly open.
HUUM manual: download PDF
Delivery in 30 business days. Supply only: installation and electrical connection are quoted separately. Euphorium is a HUUM certified installer: we supply, install and service HUUM heaters.
Prices exclude VAT.